Mechanical Components

Elkohalter Kondensatorenhalter Isolierkappe Isolierscheibe

Developed out of necessity in 2000, continuously developed and continued. Due to a faulty design of the circuit board with conductor traces under a 4-pin high-voltage SnapIn capacitor, the required creepage distances were no longer kept. The layouter had not seen the riveting of the SnapIn claw as a live part in his layout program. Since the circuit boards were already finished and the customer was already in backorder, an insulating washer ..